VX Won't Pass the "+" Symbol (E.164 Compliance)
Problem
The VX Enterprise or VX Prime Plus running firmware 1.1.0.3 or earlier does not properly register to PBXs or providers that conform to the E.164 standard.
This is caused by registration strings that convert the "+" symbol to "%2B". For example, "+12162417225" is sent as "%2B12162417225", resulting in a failed registration attempt.
Solution
This issue was addressed and fixed in a later release of firmware. At the time this article was written (May 2022), the latest release is 1.3.1, and can be found here.
Let us know how we can help
If you have further questions on this topic or have ideas about improving this document, please contact us.